Electric Steam Generator
-
48kw electric steam generator for hospital
How to clean the laundry in the hospital laundry room?The steam generator is their secret weapon
Hospitals are places where germs are concentrated. After patients are hospitalized, they will use the clothes, sheets, and quilts issued by the hospital uniformly, ranging from a few days to several months. Bloodstains and even germs from patients will inevitably be stained on these clothes. How does the hospital clean and disinfect these clothes? -
9kw Electric Steam Generator
How to choose the right type of steam generator
When choosing a steam generator model, everyone should first clarify the amount of steam used, and then decide to use a steam generator with the corresponding power. Let us let the steam generator manufacturer introduce you.
There are generally three methods for calculating steam usage:
1. The steam consumption is calculated according to the heat transfer calculation formula. Heat transfer equations typically estimate steam usage by analyzing the heat output of the equipment. This method is more complicated, because some factors are unstable, and the results obtained may have certain errors.
2. A flow meter can be used to perform a direct measurement based on steam usage.
3. Apply the rated thermal power given by the equipment manufacturer. Equipment manufacturers usually indicate the standard rated thermal power on the equipment identification plate. Rated heating power is usually used to mark the heat output in KW, while the steam usage in kg/h depends on the selected steam pressure. -
skid-mounted integrated 720kw steam generator
Advantages of skid-mounted integrated steam generator
1. Overall design
The skid-mounted integrated steam generator has its own fuel tank, water tank and water softener, and can be used when connected to water and electricity, eliminating the trouble of piping layout. In addition, a steel tray is added at the bottom of the steam generator for convenience, which is convenient for overall movement and use, which is worry-free and convenient.
2. Water softener purifies water quality
The skid-mounted integrated steam generator is equipped with three-stage soft water treatment, which can automatically purify the water quality, effectively remove calcium, magnesium and other scaling ions in the water, and make the steam equipment perform better.
3. Low energy consumption and high thermal efficiency
In addition to low energy consumption, the oil-fired steam generator has the characteristics of high combustion rate, large heating surface, low exhaust gas temperature, and less heat loss. -
360kw Electric Industrial Steam Generator
How to save time and effort in fruit wine fermentation?
There are countless types of fruits in the world, and regular consumption of fruits will also be beneficial to your health, but frequent consumption of fruits can also make people bored, so many people will make fruit into fruit wine.
The brewing method of fruit wine is simple and easy to master, and the alcohol content in the fruit wine is low, which is beneficial to health. Some common fruits in the market can also be made into fruit wine.
The technological process of fruit wine brewing: fresh fruit → sorting → crushing, destemming → fruit pulp → separation and extraction of juice → clarification → clear juice → fermentation → barrel pouring → wine storage → filtration → cold treatment → blending → filtration → finished product.
Fermentation is an important step in fruit wine brewing. It uses the fermentation of yeast and its enzymes to metabolize the sugar in fruit or fruit juice into alcohol, and uses it to inhibit the growth of harmful microorganisms. -
64kw Electric Steam Generator
A steam generator is an industrial boiler that heats water to a certain temperature and generates high-temperature steam. It is a large thermal energy device. During the working process of the boiler, the enterprise must consider its use cost to ensure that it conforms to the principle of economical and practical use and minimize the cost.
Boiler room construction and its material costs
The construction of the steam boiler boiler room belongs to the scope of civil engineering, and the construction standards must comply with the relevant provisions of the “Steam Boiler Regulations”. Boiler room water treatment agents, deslagging agents, lubricating fluids, reducing agents, etc. are billed according to the total annual consumption, and discounts are apportioned per ton of steam, and are included in the fixed cost when calculating.
But the steam generator does not need to build a boiler room, and the cost is negligible. -
1080kw Electric Steam Generator
Factory production consumes a lot of steam every day. How to save energy, reduce energy consumption, and reduce the operating costs of enterprises is a problem that every business owner is very concerned about. Let’s cut to the chase. Today we will talk about the cost of producing 1 ton of steam by steam equipment on the market. We assume 300 working days a year and the equipment runs 10 hours a day. The comparison between Nobeth steam generator and other boilers is shown in the table below.
Steam equipment Fuel energy consumption Fuel unit price 1 ton of steam energy consumption (RMB/h) 1-year fuel cost Nobeth Steam Generator 63m3/h 3.5/m3 220.5 661500 Oil boiler 65kg/h 8/kg 520 1560000 gas boiler 85m3/h 3.5/m3 297.5 892500 Coal-fired boiler 0.2kg/h 530/t 106 318000 electric boiler 700kw/h 1/kw 700 2100000 Biomass boiler 0.2kg/h 1000/t 200 600000 clarify:
Biomass boiler 0.2kg/h 1000 yuan/t 200 600000
Fuel cost of 1 ton of steam for 1 year
1. The unit price of energy in each region fluctuates greatly, and the historical average is taken. For details, please convert according to the actual local unit price.
2. The annual fuel cost of coal-fired boilers is the lowest, but the tail gas pollution of coal-fired boilers is serious, and the state has ordered to ban them;
3. The energy consumption of biomass boilers is also relatively low, and the same waste gas emission problem has been partially banned in the first and second tier cities in the Pearl River Delta;
4. Electric boilers have the highest energy consumption cost;
5. Excluding coal-fired boilers, Nobeth steam generators have the lowest fuel costs. -
54kw Electric Steam Generator
Everyone knows that a steam generator is a device that generates high-temperature steam by heating water. These high-temperature steam can be used for heating, disinfection, sterilization, etc., so what is the process of steam generator generating steam? Briefly explain the overall process of the steam generator to generate steam for you, so that you can better understand our steam generator.
-
18kw Electric Steam Generator
The setting of the steam generator expansion tank is basically indispensable for the atmospheric pressure steam generator. It can not only absorb the thermal expansion caused by the heating of the pot water, but also increase the water volume of the steam generator to avoid being evacuated by the water pump. It can also To accommodate the circulating hot water that flows back if the opening and closing valve closes laggardly or is not closed tightly when the pump stops.
For the atmospheric pressure hot water steam generator with a relatively large drum capacity, some space can be left on the upper part of the drum, and this space must be connected to the atmosphere. For common steam generators, it is necessary to set up a steam generator expansion tank communicating with the atmosphere. The steam generator expansion tank is usually located above the steam generator, the height of the tank is usually about 1 meter, and the capacity is generally not more than 2m3. -
90kw Electric Steam Generator for Food Industry
A steam generator is a special kind of equipment. Well water and river water cannot be used according to regulations. Some people are curious about the consequences of using well water. Because there are many minerals in the water, it is not treated with water. While some water may appear clear without turbidity, minerals in untreated water undergo more chemical reactions after repeated boiling in a boiler. They will stick to the heating tubes and level controls.
-
60kw Electric Steam Generator for bakery
When baking bread, the bakery can set the temperature based on the size and shape of the dough. Temperature is even more important for bread toasting. How do I keep the temperature of my bread oven within range? At this time, an electric heating steam generator is needed. The electric steam generator emits steam in 30 seconds, which can continuously control the temperature of the oven.
Steam can gelatinize the skin of bread dough. During gelatinization, the skin of the dough becomes elastic and tough. When the bread encounters cold air after baking, the skin will shrink, forming a crunchy texture.
After the bread dough is steamed, the surface humidity changes, which can prolong the drying time of the skin, keep the dough from deforming, prolong the expansion time of the dough, and the volume of the baked bread will increase and expand.
The temperature of water vapor is greater than 100°C, spraying on the surface of the dough can transfer heat to the dough.
Good bread making requires controlled steam introduction. The entire baking process does not use steam. Usually only in the first few minutes of the bake phase. The amount of steam is more or less, the time is long or short, and the temperature is high or low. Adjust according to the actual situation. Tengyang bread baking electric steam generator has fast gas production speed and high thermal efficiency. The power can be adjusted in four levels, and the power can be adjusted according to the demand of steam volume. It controls the amount of steam and temperature well, making it great for bread baking. -
360kw Electric Steam Generator
Common faults and solutions of electric heating steam generator:
1. The generator cannot generate steam. Cause: The switch fuse is broken; the heat pipe is burned; the contactor does not work; the control board is faulty. Solution: Replace the fuse of the corresponding current; Replace the heat pipe; Replace the contactor; Repair or replace the control board. According to our maintenance experience, the most common faulty components on the control board are two triodes and two relays, and their sockets are in poor contact. In addition, various switches on the operation panel are also prone to failure.2. The water pump does not supply water. Reasons: the fuse is broken; the water pump motor is burned; the contactor does not work; the control board is faulty; some parts of the water pump are damaged. Solution: replace the fuse; repair or replace the motor; replace the contactor; replace damaged parts.
3. The water level control is abnormal. Reasons: electrode fouling; control board failure; intermediate relay failure. Solution: remove the electrode dirt; repair or replace the control board components; replace the intermediate relay.
4. The pressure deviates from the given pressure range. Reason: deviation of pressure relay; failure of pressure relay. Solution: readjust the given pressure of the pressure switch; replace the pressure switch.
-
54kw Electric Steam Generator
How to use, Maintenance and Repair of Electric Heating Steam Generator
In order to ensure the normal and safe operation of the generator and prolong the service life of the equipment, the following rules of use should be observed:1. The medium water should be clean, non-corrosive and impurity-free.
Generally, soft water after water treatment or water filtered by a filter tank is used.2. In order to ensure that the safety valve is in good condition, the safety valve should be artificially exhausted 3 to 5 times before the end of each shift; if the safety valve is found to be lagging or stuck, the safety valve must be repaired or replaced before it can be put into operation again.
3. The electrodes of the water level controller should be cleaned regularly to prevent the electric control failure caused by electrode fouling. Use a #00 abrasive cloth to remove any buildup from the electrodes. This work must be done with no steam pressure on the equipment and with the power cut off.
4. In order to ensure that there is no or little scaling in the cylinder, the cylinder must be cleaned once every shift.
5. In order to ensure the normal operation of the generator, it must be cleaned once every 300 hours of operation, including electrodes, heating elements, inner walls of cylinders, and various connectors.
6. In order to ensure the safe operation of the generator; the generator must be checked regularly. Regularly inspected items include water level controllers, circuits, the tightness of all valves and connecting pipes, the use and maintenance of various instruments, and their reliability. and precision. Pressure gauges, pressure relays and safety valves must be sent to the superior measurement department for calibration and sealing at least once a year before they can be used.
7. The generator should be inspected once a year, and the safety inspection should be reported to the local labor department and carried out under its supervision.