A:The first possibility of this failure is the failure of the valve. If the valve disc falls inside the electric heating steam generator, it will block the hot gas flow channel. The solution is to open the valve gland for repair, or replace the failed valve. The second possibility is that there is too much gas in the gas collecting tank, which blocks the pipeline. The solution is to open the exhaust accessories set in the system, such as the manual air release door on the radiator, the exhaust valve on the gas collection tank, etc. There are two main ways to find blocked pipelines: hand touch and water. The method of hand touch is that where the temperature is low, there is a problem. The method of releasing water is to release water segment by segment, and drain water in the middle of different pipes. If the water at one end continues to flow forward, there is no problem with this end; if it turns back after flowing for a while, it means that this end is blocked, just disassemble this section of the pipe and take out the blockage.
Post time: Apr-21-2023